Autoclave Getinge Hs 44- Steam Sterilizer
The Getinge HS44 is a fully automatic steam sterilizer. It has pre-set programs for the most common sterilization processes for general-purpose hospital use. The program cycles employ mechanical air removal with a series of vacuum/pressure pulses to effectively remove air for assured sterilization. The chamber dimensions are adapted to sterilization, using wire baskets according to SPRI & ISO, or containers according to DIN.
Application
A sterilizer for general-purpose steam sterilization of surgical instruments, textiles and hospital utensils in central sterilization departments, operation departments, laboratories and laundries. The temperature range is from 105°C–135°C.
Chamber Volume & Size Capacity
The sterilizer chamber has a capacity of:
• 1 STU = 600x300x300 mm
• 1 ISO = 600x400x200 mm
• 1 SPRI = 585x395x195 mm
Door Selection
• Single Door
• Double Door
Service Access
• From control side. Installation Selections
• Recessed Through Wall (R) [Single Door]
• Cabinet Enclosure (C) [Single Door]
• Recessed Through Two Walls (R) [Double Door]
• Recessed Through Wall with Cabinet (M) [Double Door]
• Non-control side fascia panel recessed through wall.
Electrical Components
Terminals, contactors etc. are housed in a water-tight cabi- net (IP54). Other electrical components e.g. switches and valves are mounted directly on the sterilizer. Electrical cabinet placement is fully accessable from the front of the sterilizer.
Voltage Supply
Please refer to utility data table for correct amperage.
• HS 4406
• HS 4410 Model
• Chamber dim.
• WxHxD mm Usable space
• WxHxD mm • Vol. Litres
• HS 4406 450 x 450x 660 432 x 432x 660 137
• HS 4410 450 x 450x 1000 432 x 432x 1000 206
• Model STU ISO SPRI
• HS 4406 1.5 2 2
• HS 4410 2.5 2 2 230 V 3 phase 50 Hz 230 V 3 phase 60 Hz 400 V 3 phase 50 Hz
Pulse Vacuum Steam Sterilizer
(Standard Type)
Application LAOKEN bench top steam sterilizers can be applied to dental clinics, dental department of hospitals, ophthal- mology department, Operating rooms and so on. It can sterilize A, B class cavity instruments, dressing material, catheters and other dental instruments.*
Specifications
Automatic wash & maintenance
• CE marked and abide by EN13060 directive
• Microcomputer control with dynamic LCD display for running status, temperature, pressure and time
• Multiple pulse vacuum and positive pressure exhausting combined for guarantied steam saturation level
• Imported vacuum pump can reach -0.85bar Motorola precision pressure sensor which can monitor 0.001 bar (1KPa)
• Sterilization programs for naked instruments, packed instruments, hemophilus and glassware
• PWM temperature control of chamber and jacket, saving power and water
• Self inspection function to monitor the whole sterilizing process and save relative record for validation analysis
• Smart pulse vacuum deep dry function, dressing material humidity less than 1%, naked instruments humidity less than 0.2%
• Two groups of independent temperature sensors for program control and system monitoring, eliminating sterilization failure due to
• Temperature sensor failure or incorrect monitoring temperature value
• Built-in micro printer together with USB port to export cycle data
• Built-in memory for 50 cycles data
• Built-in smart help system for sterilization guidance Visual and vocal alarm when cycle ends or error occurs
• 1button water refill with quick coupler Automatic cycle shut off